Surge vs Running Watts
Motors need a burst of power to start. If the station can't supply it, the appliance won't start.
Running watts are what an appliance uses once it's on; surge or starting watts are the brief spike, often two to five times higher, that motors in fridges, pumps and air conditioners need for a second or two to start, and a station's peak rating has to cover it.
What surges
| Appliance | Running watts | Typical start-up surge |
|---|---|---|
| Full-size fridge | 100 to 200W | 600 to 1,500W |
| Chest freezer | 80 to 150W | 500 to 1,000W |
| Sump pump, 1/3 hp | About 800W | 1,300 to 2,000W |
| Window AC, 5,000 BTU | About 450W | About 1,000W |
| Well pump, 1/2 hp (240V) | About 1,000W | 2,000W+ |
| Microwave, coffee maker, heater | Same as rated | Little or none |
These are typical ranges; your appliance's label or manual has the real numbers. Heating appliances like kettles and space heaters don't surge.
Matching a station
Check two ratings. The continuous output must exceed the total running watts of everything on at once. The surge or peak rating must exceed that total plus the extra start-up draw of the biggest motor. Stations list surge differently, from "peak" to "surge" to "X-Boost" or "Power Lifting"; X-Boost and Power Lifting are modes that lower voltage for heaters and don't help with motor starts.
Soft starters
A soft-start kit, common for RV and window air conditioners, ramps up the compressor and can cut start-up surge by half or more, which lets a smaller station start a bigger AC.
Questions
What happens if surge is too high?
The station's overload protection shuts its AC output off. Most reset on their own or with a button press.
Do I need more surge for a fridge?
Most stations with 1,500W or more of output start full-size fridges. Small 300 to 600W stations often can't.